ASTM D3385 PDF

Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer. ASTM D Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer. standard by ASTM International. GeoTesting Express is a provider of Soil Testing Services – ASTM D, Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring.

Author: Akinorisar Malahn
Country: Equatorial Guinea
Language: English (Spanish)
Genre: Environment
Published (Last): 2 February 2014
Pages: 361
PDF File Size: 6.80 Mb
ePub File Size: 18.11 Mb
ISBN: 644-6-21256-572-5
Downloads: 77831
Price: Free* [*Free Regsitration Required]
Uploader: Yozshugor

They are also helpful in determining irrigation requirements, water spreading or recharge, canal leakage and reservoir leakage testing and studies. Nails, Spikes, and Staples.

Users of this standard are cautioned that compliance with Practice D does not in itself assure reliable results. Enter your account email address to xstm a password reset: Users of this standard are cautioned that compliance with Practice D does not in itself assure reliable results. Turf-Tec offers many different ways of performing infiltration tests.

These rings provide an ASTM approved double ring infiltration test which provides a soil infiltration test in a simple yet efficient manner. The inch-pound units given in parentheses are mathematical conversions, which are provided for information purposes only and are not considered standard.

The purpose of the double ring is to insure the downward flow of movement of water to insure proper measurements. This test method is useful for field measurement of the infiltration rate of soils. Search book title Enter keywords for book title search. Thus, tests made at the same site are not likely to give identical results and the rate measured aastm the test method described in this standard is primarily for comparative use.

  ANDREW WILES FERMAT PROOF PDF

ASTM D3385

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine asm applicability of regulatory limitations prior to use. Many factors affect the infiltration rate, for example the soil structure, soil layering, condition of the soil surface, degree of saturation of the soil, chemical and physical nature of the soil and of the applied liquid, head of the applied liquid, temperature of the liquid, and diameter and depth of embedment of rings.

Infiltration rates have applications in the field of liquid waste disposal, evaluation of potential septic tank disposal fields, leaching studies and drainage efficiencies. Link to Active This link will always route to the current Active version of the standard.

ASTM D Standard

The purpose of the outer ring is to promote one-dimensional, vertical flow beneath the inner ring. Reliable results depend on many factors; Practice D provides a means of evaluating some of those factors. There were no books found d33885 the applied search filters.

They also contain ports to allow easy connection of Turf-Tec Mariotte Tubes. See our other infiltration devices: Double ring Infiltrometer, standard set.

Enter your personal account email address to request a password reset: Infiltration rates have application to such studies as liquid waste disposal, evaluation of potential septic-tank disposal fields, leaching and drainage efficiencies, irrigation requirements, water spreading and recharge, and canal or reservoir leakage, among other applications. They cannot be directly related unless the hydraulic boundary conditions are known, such as hydraulic gradient and the extent of lateral flow of water, or can be reliably estimated.

These Infiltration rings are constructed of heavy duty 16 Gauge. They cannot be directly related unless the hydraulic boundary conditions are known, such as hydraulic gradient and the extent of lateral flow of water, or can be reliably estimated. Register d33385 a trial account.

  ESAP IN ZIMBABWE PDF

Turf-Tec International Infiltration Rings – 12 and 24 Inch Diameters for ASTM

Although the units of infiltration rate and hydraulic conductivity of soils are similar, there is a distinct difference between these two quantities. However, this test method cannot be conducted where the test surface is below the groundwater table or perched water table.

Remember me for one month. This test method is useful for field measurement of the infiltration rate of soils.

Active Risk Management

The purpose of the outer ring is to promote one-dimensional, vertical flow beneath the inner ring. Significance aztm Use This test method is useful for field measurement of the infiltration rate of soils. Turf-Tec 12″ and 24″ infiltration rings are already centered in position for ease of positioning rings and ease of insertion into the soil. Although the units of infiltration rate and hydraulic conductivity of soils are similar, there is a xstm difference between these two quantities.

Some aspects of the test, such as the length of time the tests should be conducted and the head of liquid to be applied, must depend upon the experience of the user, the purpose for testing, and the kind of information that is sought. Atsm Version s – view previous versions of standard.

VPN